DISASTER PLANNING FOR COMPUTERS AND NETWORKS
By Richard W. Boss
Libraries are subject to disasters, both natural and manmade. It is essential
to plan for them in order to prevent them when possible and to recover
from them as quickly as possible when they do occur. This Tech Note is
limited to disaster planning for computers and networks, but libraries
should undertake disaster planning on a comprehensive basis, with the
protection of computers and networks but one component of its disaster
plan.
Disaster planning for computers and networks is important because these
technologies are essential to patron service and staff productivity. Not
only is the patron access catalog the only way for patrons to identify
holdings and current availability of titles in their library, but also
titles in other libraries and electronic resources to which their library
subscribes. For many, their only access to the Internet is through their
library. Library staff are dependent on these technologies for ordering,
claiming and receiving library materials, charging and discharging of
library materials to patrons; and the provision of reference service.
Every hour of downtime is extremely serious, therefore, a library must
give disaster planning a high priority.
Definition
A disaster is defined as a sudden misfortune that is ruinous to an undertaking.
This means that there is little time to react at the time of the misfortune.
Preparations have to have been made in advance. The focus should, therefore,
be on disaster planning.
Risk Assessment
A computer or network disaster typically involves loss of or damage to
data, the inability of programs to function, or the loss of data communication.
The first step in disaster planning is to assess risk. What is the probability
a particular disaster will occur and how serious is the effect likely
to be if it does occur? Among the disasters that should be assessed are
natural disasters such as floods, fires, and earthquakes and manmade disasters
such as air conditioning failures, viruses, hacking, and vandalism. The
line between the two is not clear-cut because a flood can be the result
of vandalism to a water pipe and a fire can be deliberately set as an
act of vandalism.
A risk assessment matrix should be created, one which puts the probability
on one axis and the effect on the other, with the risk factor fixed by
the combination of the two factors:
EFFECT Major Moderate Minor High 5 4 3 PROBABILITY Moderate 4 3 2 Low
3 2 1
A risk factor of 5 requires much more attention and warrants a much greater
outlay of resources than a risk factor of 1.
The risk factor will vary by area of the country, nature of the community,
and type of organization. In much of California, earthquakes would be
rated a risk factor of 5; along the flood plains of the Mississippi River
flooding would be a risk factor of 5. Viruses, while probable, usually
have only a minor effect, therefore, they would have a risk factor of
3. Hacking, which rates highly probably for Fortune 500 companies, rates
low for libraries, but may rate a risk factor of 3 because its effect
may be major. In many areas floods are likely to be the result of a broken
pipe and have a low risk factor of 1 or 2 because their effect tends to
be localized and, therefore, minor or moderate.
Risk Reduction
The second step in disaster planning is risk reduction. This is achieved
by lowering the risk factor by reducing the probability, reducing the
effect, or both. For example, while no disaster plan can reduce the probability
of an earthquake, building a library in California that is quake-resistant
should reduce the effect of one. Placing a computer room where there are
no overhead pipes reduces the probability of flooding; rack-mounting the
computer hardware so that it is several inches above the floor reduces
the effect. Installing anti-virus software reduces the probability of
a disaster; regularly backing up all data reduces the effect.
Needed Resources
Disaster planning takes time and expertise, but it is within the means
of most libraries. A small task force of staff members, given time to
read the literature and contact other libraries that have done disaster
planning, can develop a disaster plan in weeks or months. What is difficult
for many libraries is finding the funds to carry out the plan. Retrofitting
an old building to withstand earthquakes can cost hundreds-of-thousands
or millions of dollars; mirroring a library's database of bibliographic
and patron records can cost tens-of-thousands of dollars. Each risk factor
must, therefore, have a price tag associated with it. A library has to
decide whether the risk reduction is worth the price and, if so, seek
the funds to pursue the risk reduction.
It may not be realistic to lower the highest risk factors first because
the funds may not be available. It may be necessary to focus on lowering
risk factors for which the resources are available. Heat/smoke and water
detectors are within the means of most libraries and should not be skipped
over just because the risk factor is not a 4 or 5.
Common Disaster Plan Elements
Every disaster plan should set forth both preventive measures and remedies
in at least the following areas:
Servers
Every library with one or more servers should have a server room that
is secured with a combination lock such as a Simplex and a reinforced
door with a deadbolt at last 1.5 inches long. If the room is not windowless,
the windows should be barred. The room should have both fire/heat detection
and water detection sensors which set off a local alarm and send a signal
to an off-premises monitoring facility. At a minimum, it should have
fire extinguishers suitable for electrical fires. A library that has
hundreds-of-thousands of dollars in equipment in its server room should
consider a built-in fire suppression system.
Excess heat is, by far, the most commonly reported cause of server
downtime and damage. A library should, therefore, augment its building
air conditioning with a room-size air conditioner that kicks-in only
when its thermostat shows that the temperature in the room has risen
above a library specified level, typically 68 degrees. An additional
safeguard is available, a thermostat inside any cabinet which has a
cooling fan. When a fan fails and the temperature rises, an alarm should
be triggered.
Water damage is the second-ranking cause of server downtime and damage,
although the damage is rarely greater than moderate. There should be
no water pipes in the ceiling above the room, or in the walls that enclose
it. The server(s) and associated peripheral equipment should be rack-mounted
so that up to six inches of standing water will not affect the equipment.
Power irregularities are the third-ranking cause of server downtime
and damage. An UPS (uninterruptible power supply) should be used to
protect all servers against surges, spikes, brownouts, and blackouts.
The UPS should have a rating which is it least twice the total KVA requirements
of the devices it protects. KVA (Kilo Volt Amperes) is a rating that
is calculated by multiplying the number of volts by the number of amperes
and dividing by 1,000. While a library may not want to operate its servers
on battery back-up for an extended period, the UPS should provide power
long enough for an orderly shutdown of all servers.
The database server should be protected by its own firewall, preferably
a proxy-server between it and the Web server on which the patron access
catalog is mounted. A proxy server shields the database server from
direct access by initiating a separate inquiry, rather than passing
the external inquiry through to the database server. The firewall can
be on the same hardware platform as the database server. The Web server
can support not only the patron access catalog, but also other files
and a gateway to electronic resources outside the library. It should
include remote patron authentication software so that access to other
than records the library wishes to make available to everyone is limited
to those who are registered library users.
Each server should be configured with a logging tape drive--typically
a 4mm or 8mm streaming tape drive-- so that all information written
to disk is also written to tape. Each evening the logging tape should
be removed and stored away from the server room and a new tape mounted
for database back-up. Overnight, the content of the disk drives should
be written to tape. The next morning, the back-up tape should be removed
and stored away from the server room and a new tape mounted for logging
that day's transactions. It will then be possible to restore all files
using the most recent back and logging tapes. Magnetic media can become
unstable with repeated use, therefore, seven logging tapes--one for
each day of the week--should be used. Seven back-up tapes should also
be used. All of the tapes should be replaced at least every year.
A library may choose to do a back-up only once a week. If so, all of
the logging tapes for the week should be saved so that they and the
previous week's back-up tape can be used to restore the files. The logging
tapes and the previous week's back-up tape should be stored away from
the server room. In a large facility than may be at the opposite end
of the building, but for smaller facilities it should be off-site.
At least once per week, a current back-up tape should be sent to an
off-site storage facility to protect against the loss of the on-site
back-up tape.
Libraries that can afford RAID (Reduced Array of Inexpensive Disks)
should configure their servers with them. RAID technology mirrors everything
written to one disk on another disk. If a disk fails, the mirroring
disk provides access to the information without resorting to the rebuilding
of files from the combination of back-up and logging tapes.
The database server for the automated library system should be available
only to library staff in the library and the vendor of the automated
library system. It should not be available to others via the Internet
or by dial-up. Patrons should instead, access the patron access catalog
on a Web server.
Network
A library can do a great deal to secure a LAN (local area network),
but only a limited amount to secure a WAN (wide area network). The former
usually is limited to a single building or part of a building; the latter
usually ties two or more LANs together using a telco or other common
carrier's circuits. The telco or common carrier has the responsibility
for its portion of the WAN.
The preferred LAN topology is a hybrid star, one that has several central
star network points linked in a star. In other words, several desktop
clients are connected to a hub, and several hubs are connected to yet
another hub. The cabling from the desktop clients to the hubs can be
relatively inexpensive Category 5 UTP (unshielded twisted pair); the
wiring among hubs should be STP (shielded twisted pair) or fiber optic
to dramatically improve performance and security.
Network hardware should be secured in locked data communications closets
or cabinets. All data jacks should be capable of being de-activated
when no library equipment is connected to them. The practice of distributing
a large number of data jacks around a building for use by patrons with
laptops should be avoided unless these jacks are on a separate LAN segment
that can be isolated from the database server of the automated library
system. Patrons need access only to the patron access catalog, and possibly
to other servers: Web, Internet, CD-ROM, image, etc.
If a wireless LAN is implemented, it should access only a segment of
the library's LAN, one that can be isolated from the database server
of the automated library system.
The most vulnerable part of a library's network is the connection to
the Internet, both access from the Internet to its servers and from
its servers and clients to the Internet. Fortunately, it is cost effective
to protect a library's database server with its own firewall so that
there is protection against in-library users, as well as external users.
More vulnerable are the other servers and the clients or desktop workstations.
Most libraries seek to protect them only from users outside the library.
This can be done by installing a network firewall. The firewall can
be configured not only to restrict access to specific categories of
users or specific types of queries, but can also be configured to facilitate
access to library-selected resources.
Clients
PCS and Macs are the most vulnerable technology in libraries because
they can be compromised by staff and patrons who behave unwisely by
downloading attachments or bringing in software and data disks from
outside the library. Viruses are the greatest threat. Anti-virus software
is absolutely essential. Products from companies such as McAfee and
Norton detect computer virus signatures and alert the user to them before
they enter the client, however, anti- virus products are of little value
if they are not regularly updated. Literally hundreds of new viruses
are unleashed every week, therefore, anti-virus software should be updated
at least weekly by downloading the latest version.
Almost all viruses travel via e-mail attachments or diskettes. Staff
should, therefore, be instructed not to open an attachment if the source
of the e-mail is not known or the attachment is not expected. They should
be particularly suspicious of attachments with strange-sounding titles.
When in doubt, the sender should be asked by return e-mail to describe
the contents of the attachment. Staff should be instructed not to bring
software from home for loading on library machines, nor to carry diskettes
back and forth ("sneakernet") between home and work machines.
Recovery Procedures
It is important to state in the disaster plan not only what recovery
procedures are to be followed if a disaster occurs, but also who has what
responsibility. Who calls whom and what information should they be prepared
to give? Who performs the needed diagnostics? Who restores the files?
What are the instructions for packing and shipping the corrupted files?
Communication
Communication is of great importance during a disaster. It should not
be assumed that regular telephone service will be available. Key personnel
should have cell phones for use when regular telephone service fails
or is overloaded. The cell phone in the server room should be stored
in a wall-hung watertight cabinet on the wall adjacent to the entrance
door. The instructions for dealing with a computer/network disaster
should be stored in the same cabinet. All important telephone numbers
should be stored in each cell phone. If a disaster affects more than
the library, the cellular service may be swamped with calls. It is,
therefore, a good idea to instruct the operator in the server room to
use the redial and speaker features of the regular telephone while seeking
to get through on the cell phone.
Designated operators
There should be a server operator on duty each hour a library is open.
This may be a member of the circulation desk's support staff--the staff
which usually is in the library all of the hours a library is open.
The designated person would perform the end-of-day swap of the logging
and back-up tapes as part of his/her routine duties. Otherwise, s/he
would leave her/his regular duties only when there was a problem.
The designated operator on duty at the time of a disaster should have
instructions to call the support desks for the servers that have been
affected. The numbers should be encoded in both the server room's telephone
and the cell phone that has been provided as a back-up.
Each designated operator should participate in an occasional disaster
drill that simulates an actual disaster that affects one or more servers.
Designated manager
An operator may encounter a situation that overwhelms him/her. There
should always be a designated manager in the library or available by
telephone 24 hours per day, seven days per week. While there may rarely
be a need to decide about evacuation of the library or another major
action, the capacity to do so must be in place.
External resources
The vendor of an automated library system is an important resource
in diagnosing problems that result from a disaster. When drawing the
contract, make it clear that the vendor shall be liable not only for
the performance of the central site and its client software, but it
shall undertake remote diagnostics through the network to the desktop.
In other words, it shall pinpoint a problem regardless of where it is.
If coverage has not been purchased for 24 hours a day and seven days
a week, there should be provision for emergency support at agreed upon
hourly rates outside the normal coverage hours.
If the database server for the automated library system is affected
by a disaster, the vendor's trouble desk should be called so that remote
diagnostics can be performed and guidance can be obtained. If the vendor
of the automated library system is not responsible for the management
of hardware maintenance, hardware problems should be referred to the
manufacturer's support desk.
With few exceptions, the vendors of automated library systems operate
service bureaus for libraries that do not wish to maintain their own
computer systems. A library should discuss the terms for its vendor
to offer its service bureau as a back-up facility should the library
not be able to restore its own system within a day or so. This will
involve establishing a basic profile and maintaining a relatively recent
copy of the library's database at the vendor's site. Since access to
the server will probably be via the Internet, performance will not be
the equal of that possible with a local server.
Sources of support for all other servers should be identified and their
telephone numbers encoded in the server room's telephone and in the
cell phone that have been provided for back- up.
Most libraries do not have the luxury of a network specialist. A library
should, therefore, rely on the networking staff of a parent organization
or consider contracting with a network support service for remote diagnostics
and recovery assistance. While these firms are found in most major cities,
a regional or national firm with experience in automated library systems
should be considered.
One or more data recovery firms should be identified. These firms recover
data from hard drives, diskettes, or any other storage medium that has
been damaged by flood, fire, physical impact, or a virus. Rates range
from $50 to $100 per hour, and most recoveries require fewer than eight
hours. A large national firm usually is able to accommodate a rush order
better than a smaller local one. The media can be sent overnight by
FedEx or another courier service. It is a good idea to establish an
account ahead of time.
A library should determine whether its book jobbers and serials subscription
agencies will provide machine-readable records of orders placed with
them, how quickly they can be available, and at what cost.
Insurance
Unless it is part of a larger organization that carries disaster insurance
or is self-insuring, a library should carry insurance that includes
coverage for its servers, network, and clients. In order to make claims,
it is essential to have an absolutely current inventory of all hardware
and software, including purchase data and price. A copy of this information
should be stored at a remote site.
In case of damage that is visible, photographs should be taken promptly
after the disaster to substantiate an insurance claim.
Sources of Information
Up-to-date information on computer and network disaster planning can
be found on the Internet. Specific Web sites are not being recommended
because the information on sites quickly goes out of date. Insofar as
possible, consult only sites which date their information or which clearly
have current information--for example, sites which refer to current versions
of standards. However, one site that has regularly been updated is worth
mentioning: Intra Computer Inc.'s site on disasters in computer rooms.
It can be found at www.intraocomp.com/.
Disaster planning guidelines do not go out of date as quickly. An excellent
source for information is a paper written and by Dr. Jan Lyall, Director,
National Preservation Office, National Library of Australia in 1993 and
presented at an international conference. It is still available at www.nla.gov.au/nla/staffpaper/lyall1.html/.
While the guidelines were developed with the protection of library materials
in mind, they are useful in any disaster planning.
June 2002
|